Feed Inlet Devices

 

 

Feed inlet devices including half open pipe/ baffle and vane distributor would be added to the separator drum inlet nozzle, depending on configurations and process specifications to gain one or more of following advantages:

  • Minimum liquid droplet entrance to the mist eliminator
  • Lower vapor velocity
  • Lower re-entrainment
  • Smaller nozzle size

 

Based on the magnitude of gas momentum, 3 options are available:

  • In high Ïv2, vane inlet device is mandatory
  • In moderate ρv2, inlet baffle or half open pipe is used
  • In low ρv2, no inlet device is recommended

Contact

INTRA Process Equipment

Semperstr. 29

D-44801 Bochum

Tel.: + 49 (0) 2327 / 60 290 - 0
Fax: + 49 (0) 2327 / 60 290 - 44

 Email